JOZE00POL Site Information Form (site log)
     International GNSS Service
     See Instructions at:
       https://files.igscb.org/pub/station/general/sitelog_instr.txt


0.   Form

     Prepared by (full name)  : Tomasz Liwosz
     Date Prepared            : 2021-07-30
     Report Type              : UPDATE
     If Update:
      Previous Site Log       : joze00pol_20201006.log
      Modified/Added Sections : 3.6, 3.7, 11


1.   Site Identification of the GNSS Monument

     Site Name                : JOZEFOSLAW
     Four Character ID        : JOZE
     Monument Inscription     : stable geodynamical pillar
     IERS DOMES Number        : 12204M001
     CDP Number               : (A4)
     Monument Description     : Pillar
       Height of the Monument : 1.0 m
       Monument Foundation    : CONCRETE
       Foundation Depth       : 2.5 m
     Marker Description       : forced centered plate
     Date Installed           : 1993-08-03
     Geologic Characteristic  : clay
       Bedrock Type           : SEDIMENTARY
       Bedrock Condition      : (FRESH/JOINTED/WEATHERED)
       Fracture Spacing       : (0 cm/1-10 cm/11-50 cm/51-200 cm/over 200 cm)
       Fault zones nearby     : Teisseyre
         Distance/activity    : (multiple lines)
     Additional Information   : point of IGS, EUREF, EPOCH-92, CERGOP,
                              : CERGOP2,geodyn. network EXTENDED SAGET
                              : IERS DOMES Number by Altamimi, 22-NOV-93


2.   Site Location Information

     City or Town             : Jozefoslaw
     State or Province        : Mazovian
     Country                  : Poland
     Tectonic Plate           : EURASIAN
     Approximate Position (ITRF)
       X coordinate (m)       : 3664940.500
       Y coordinate (m)       : 1409153.590
       Z coordinate (m)       : 5009571.170
       Latitude (N is +)      : +520550.18
       Longitude (E is +)     : +0210153.52
       Elevation (m,ellips.)  : 141.4
     Additional Information   : Near Warsaw


3.   GNSS Receiver Information

3.1  Receiver Type            : TRIMBLE 4000SSE
     Satellite System         : GPS
     Serial Number            : 2090
     Firmware Version         : NP 7.19; SP 3.04
     Elevation Cutoff Setting : 0 deg
     Date Installed           : 1993-08-03
     Date Removed             : 2009-05-21T11:00Z
     Temperature Stabiliz.    : 19.0 +/- 1.0
     Additional Information   : (multiple lines)

3.2  Receiver Type            : TRIMBLE 4000SSI
     Satellite System         : GPS
     Serial Number            : 4002A27500
     Firmware Version         : 7.29
     Elevation Cutoff Setting : 0 deg
     Date Installed           : 2009-05-21T12:00Z
     Date Removed             : 2018-10-11
     Temperature Stabiliz.    : 19.0 +/- 1.0
     Additional Information   : (multiple lines)

3.3  Receiver Type            : SEPT POLARX5
     Satellite System         : GPS+GLO+GAL+BDS+QZSS+IRNSS+SBAS
     Serial Number            : 3013909
     Firmware Version         : 5.2.0
     Elevation Cutoff Setting : 0 deg
     Date Installed           : 2018-10-25T16:49Z
     Date Removed             : 2020-02-05T12:13Z
     Temperature Stabiliz.    : 21.0 +/- 1.0
     Additional Information   : (multiple lines)

3.4  Receiver Type            : SEPT POLARX5
     Satellite System         : GPS+GLO+GAL+BDS+QZSS+IRNSS+SBAS
     Serial Number            : 3013909
     Firmware Version         : 5.3.2
     Elevation Cutoff Setting : 0 deg
     Date Installed           : 2020-02-05T12:19Z
     Date Removed             : 2020-06-18T09:00Z
     Temperature Stabiliz.    : 21.0 +/- 1.0
     Additional Information   : Receiver failure.

3.5  Receiver Type            : SEPT POLARX5S
     Satellite System         : GPS+GLO+GAL+BDS+QZSS+IRNSS+SBAS
     Serial Number            : 3022664
     Firmware Version         : 5.3.2
     Elevation Cutoff Setting : 0 deg
     Date Installed           : 2020-06-25T17:17Z
     Date Removed             : 2020-07-30T12:00Z
     Temperature Stabiliz.    : 21.0 +/- 1.0
     Additional Information   : (multiple lines)

3.6  Receiver Type            : SEPT POLARX5
     Satellite System         : GPS+GLO+GAL+BDS+QZSS+IRNSS+SBAS
     Serial Number            : 3234281
     Firmware Version         : 5.3.2
     Elevation Cutoff Setting : 0 deg
     Date Installed           : 2020-07-30T12:26Z
     Date Removed             : 2021-07-30T13:02Z
     Temperature Stabiliz.    : 21.0 +/- 1.0
     Additional Information   : (multiple lines)

3.7  Receiver Type            : SEPT POLARX5
     Satellite System         : GPS+GLO+GAL+BDS+QZSS+IRNSS+SBAS
     Serial Number            : 3234281
     Firmware Version         : 5.4.0
     Elevation Cutoff Setting : 0 deg
     Date Installed           : 2021-07-30T13:02Z
     Date Removed             : CCYY-MM-DDThh:mmZ
     Temperature Stabiliz.    : 21.0 +/- 1.0
     Additional Information   : (multiple lines)

3.x  Receiver Type            : (A20, from rcvr_ant.tab; see instructions)
     Satellite System         : (GPS+GLO+GAL+BDS+QZSS+IRNSS+SBAS)
     Serial Number            : (A20, but note the first A5 is used in SINEX)
     Firmware Version         : (A11)
     Elevation Cutoff Setting : (deg)
     Date Installed           : (CCYY-MM-DDThh:mmZ)
     Date Removed             : (CCYY-MM-DDThh:mmZ)
     Temperature Stabiliz.    : (none or tolerance in degrees C)
     Additional Information   : (multiple lines)


4.   GNSS Antenna Information

4.1  Antenna Type             : TRM14532.00     NONE
     Serial Number            : 23525
     Antenna Reference Point  : BPA
     Marker->ARP Up Ecc. (m)  :   0.1980
     Marker->ARP North Ecc(m) :   0.0000
     Marker->ARP East Ecc(m)  :   0.0000
     Alignment from True N    : 4 deg
     Antenna Radome Type      : NONE
     Radome Serial Number     : 
     Antenna Cable Type       : Trimble
     Antenna Cable Length     : 30 m
     Date Installed           : 1993-08-08
     Date Removed             : 2018-10-11
     Additional Information   : (multiple lines)

4.2  Antenna Type             : SEPCHOKE_B3E6   NONE
     Serial Number            : 5081
     Antenna Reference Point  : BPA
     Marker->ARP Up Ecc. (m)  :   0.1980
     Marker->ARP North Ecc(m) :   0.0000
     Marker->ARP East Ecc(m)  :   0.0000
     Alignment from True N    : 0 deg
     Antenna Radome Type      : NONE
     Radome Serial Number     : 
     Antenna Cable Type       : RG213
     Antenna Cable Length     : 30 m
     Date Installed           : 2018-10-25T16:49Z
     Date Removed             : CCYY-MM-DDThh:mmZ
     Additional Information   : (multiple lines)

4.x  Antenna Type             : (A20, from rcvr_ant.tab; see instructions)
     Serial Number            : (A*, but note the first A5 is used in SINEX)
     Antenna Reference Point  : (BPA/BCR/XXX from "antenna.gra"; see instr.)
     Marker->ARP Up Ecc. (m)  : (F8.4)
     Marker->ARP North Ecc(m) : (F8.4)
     Marker->ARP East Ecc(m)  : (F8.4)
     Alignment from True N    : (deg; + is clockwise/east)
     Antenna Radome Type      : (A4 from rcvr_ant.tab; see instructions)
     Radome Serial Number     : 
     Antenna Cable Type       : (vendor & type number)
     Antenna Cable Length     : (m)
     Date Installed           : (CCYY-MM-DDThh:mmZ)
     Date Removed             : (CCYY-MM-DDThh:mmZ)
     Additional Information   : (multiple lines)


5.   Surveyed Local Ties

5.x  Tied Marker Name         : 
     Tied Marker Usage        : (SLR/VLBI/LOCAL CONTROL/FOOTPRINT/etc)
     Tied Marker CDP Number   : (A4)
     Tied Marker DOMES Number : (A9)
     Differential Components from GNSS Marker to the tied monument (ITRS)
       dx (m)                 : (m)
       dy (m)                 : (m)
       dz (m)                 : (m)
     Accuracy (mm)            : (mm)
     Survey method            : (GPS CAMPAIGN/TRILATERATION/TRIANGULATION/etc)
     Date Measured            : (CCYY-MM-DDThh:mmZ)
     Additional Information   : (multiple lines)


6.   Frequency Standard

6.1  Standard Type            : EXTERNAL RUBIDIUM
       Input Frequency        : 10 MHz
       Effective Dates        : 1994-11-10/2005-06-30
       Notes                  : TEMEX NEUCHATEL TIME SA
                              : Frequency standard was out of order several
                              : times during this period.

6.2  Standard Type            : INTERNAL 
       Input Frequency        : (if external)
       Effective Dates        : 2005-07-01/CCYY-MM-DD
       Notes                  : (multiple lines)

6.x  Standard Type            : (INTERNAL or EXTERNAL H-MASER/CESIUM/etc)
       Input Frequency        : (if external)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Notes                  : (multiple lines)


7.   Collocation Information

7.1  Instrumentation Type     : GRAVITY
       Status                 : PERMANENT
       Effective Dates        : 2001-01-01/CCYY-MM-DD
       Notes                  : gravity tidal station no. 0909

7.x  Instrumentation Type     : (GPS/GLONASS/DORIS/PRARE/SLR/VLBI/TIME/etc)
       Status                 : (PERMANENT/MOBILE)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Notes                  : (multiple lines)


8.   Meteorological Instrumentation

8.1.1  Humidity Sensor Model  : HPTL.3A (Vaisala)
       Manufacturer           : NAVI Ltd.,Sporna 11, PL 61-709 POZNAN
       Serial Number          : 
       Data Sampling Interval :  1800 sec
       Accuracy (% rel h)     : 1 % rel h
       Aspiration             : UNASPIRATED
       Height Diff to Ant     : 1 m
       Calibration date       : 2001-10-05
       Effective Dates        : 1997-01-01/2001-10-19
       Notes                  : (multiple lines)

8.1.2  Humidity Sensor Model  : LB-710RHMS
       Manufacturer           : LAB-EL POLAND
       Serial Number          : 
       Data Sampling Interval :   900 sec
       Accuracy (% rel h)     : 2 % rel h
       Aspiration             : NATURAL
       Height Diff to Ant     : 11.1 m
       Calibration date       : 2001-10-05
       Effective Dates        : 2001-10-20/2010-08-11
       Notes                  : (multiple lines)

8.1.3  Humidity Sensor Model  : LB-710R
       Manufacturer           : LAB-EL POLAND
       Serial Number          : 
       Data Sampling Interval :   900 sec
       Accuracy (% rel h)     : 2 % rel h
       Aspiration             : NATURAL
       Height Diff to Ant     : 1.8 m
       Calibration date       : 2009-07-01
       Effective Dates        : 2010-08-12/CCYY-MM-DD
       Notes                  : (multiple lines)

8.1.x  Humidity Sensor Model  : 
       Manufacturer           : 
       Serial Number          : 
       Data Sampling Interval : (sec)
       Accuracy (% rel h)     : (% rel h)
       Aspiration             : (UNASPIRATED/NATURAL/FAN/etc)
       Height Diff to Ant     : (m)
       Calibration date       : (CCYY-MM-DD)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Notes                  : (multiple lines)

8.2.1  Pressure Sensor Model  : HPTL.3A (Vaisala)
       Manufacturer           : NAVI Ltd.,Sporna 11, PL 61-709 POZNAN
       Serial Number          : 
       Data Sampling Interval : 1800 sec
       Accuracy               : 0.2 hPa
       Height Diff to Ant     : 1 m
       Calibration date       : 2001-10-05
       Effective Dates        : 1997-01-01/2001-10-19
       Notes                  : (multiple lines)

8.2.2  Pressure Sensor Model  : LB-716
       Manufacturer           : LAB-EL POLAND
       Serial Number          : 
       Data Sampling Interval : 900 sec
       Accuracy               : 0.5 hPa
       Height Diff to Ant     : 2.5 m
       Calibration date       : 2001-10-05
       Effective Dates        : 2001-10-20/2010-08-12
       Notes                  : (multiple lines)

8.2.3  Pressure Sensor Model  : LAB-716
       Manufacturer           : LAB-EL POLAND
       Serial Number          : 
       Data Sampling Interval : 900 sec
       Accuracy               : 0.5 hPa
       Height Diff to Ant     : 0.3 m
       Calibration date       : 2009-07-01
       Effective Dates        : 2010-08-13/CCYY-MM-DD
       Notes                  : (multiple lines)

8.2.x  Pressure Sensor Model  : 
       Manufacturer           : 
       Serial Number          : 
       Data Sampling Interval : (sec)
       Accuracy               : (hPa)
       Height Diff to Ant     : (m)
       Calibration date       : (CCYY-MM-DD)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Notes                  : (multiple lines)

8.3.1  Temp. Sensor Model     : HPTL.3A (Vaisala)
       Manufacturer           : NAVI Ltd.,Sporna 11, PL 61-709 POZNAN
       Serial Number          : 
       Data Sampling Interval : 1800 sec
       Accuracy               : 0.2 deg C
       Aspiration             : UNASPIRATED
       Height Diff to Ant     : 10 m
       Calibration date       : 2001-10-05
       Effective Dates        : 1997-01-01/2001-10-19
       Notes                  : (multiple lines)

8.3.2  Temp. Sensor Model     : LB-710RHMS
       Manufacturer           : LAB-EL POLAND
       Serial Number          : 
       Data Sampling Interval : 900 sec
       Accuracy               : 0.2 deg C
       Aspiration             : NATURAL
       Height Diff to Ant     : 11.1 m
       Calibration date       : 2001-10-05
       Effective Dates        : 2001-10-20/2010-08-12
       Notes                  : (multiple lines)

8.3.3  Temp. Sensor Model     : LB-710R
       Manufacturer           : LAB-EL POLAND
       Serial Number          : 
       Data Sampling Interval : 900 sec
       Accuracy               : 0.2 deg C
       Aspiration             : NATURAL
       Height Diff to Ant     : 1.8 m
       Calibration date       : 2009-07-01
       Effective Dates        : 2010-08-13/CCYY-MM-DD
       Notes                  : (multiple lines)

8.3.x  Temp. Sensor Model     : 
       Manufacturer           : 
       Serial Number          : 
       Data Sampling Interval : (sec)
       Accuracy               : (deg C)
       Aspiration             : (UNASPIRATED/NATURAL/FAN/etc)
       Height Diff to Ant     : (m)
       Calibration date       : (CCYY-MM-DD)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Notes                  : (multiple lines)

8.4.x  Water Vapor Radiometer : 
       Manufacturer           : 
       Serial Number          : 
       Distance to Antenna    : (m)
       Height Diff to Ant     : (m)
       Calibration date       : (CCYY-MM-DD)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Notes                  : (multiple lines)

8.5.x  Other Instrumentation  : (multiple lines)


9.   Local Ongoing Conditions Possibly Affecting Computed Position

9.1.x  Radio Interferences    : (TV/CELL PHONE ANTENNA/RADAR/etc)
       Observed Degradations  : (SN RATIO/DATA GAPS/etc)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Additional Information : (multiple lines)

9.2.x  Multipath Sources      : (METAL ROOF/DOME/VLBI ANTENNA/etc)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Additional Information : (multiple lines)

9.3.1  Signal Obstructions    : TREES/BUILDINGS
       Effective Dates        : 1997-01-01/CCYY-MM-DD
       Additional Information : (multiple lines)

9.3.x  Signal Obstructions    : (TREES/BUILDINGS/etc)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Additional Information : (multiple lines)


10.  Local Episodic Effects Possibly Affecting Data Quality

10.1  Date                    : 2001-11-20/2002-03-01
      Event                   : TREE CLEARING

10.2  Date                    : 2019-12-11/2019-12-11
      Event                   : TREE CLEARING

10.x  Date                    : (CCYY-MM-DD/CCYY-MM-DD)
      Event                   : (TREE CLEARING/CONSTRUCTION/etc)


11.  On-Site, Point of Contact Agency Information

     Agency                   : Warsaw University of Technology
                              : Department of Geodesy and Geodetic Astronomy
     Preferred Abbreviation   : WUT
     Mailing Address          : pl. Politechniki 1
                              : 00-661 Warszawa
                              : Poland
     Primary Contact
       Contact Name           : Tomasz Liwosz
       Telephone (primary)    : 
       Telephone (secondary)  : 
       Fax                    : 
       E-mail                 : tomasz.liwosz@pw.edu.pl
     Secondary Contact
       Contact Name           : 
       Telephone (primary)    : 
       Telephone (secondary)  : 
       Fax                    : 
       E-mail                 : 
     Additional Information   : (multiple lines)




12.  Responsible Agency (if different from 11.)

     Agency                   : (multiple lines)
     Preferred Abbreviation   : (A10)
     Mailing Address          : (multiple lines)
     Primary Contact
       Contact Name           : 
       Telephone (primary)    : 
       Telephone (secondary)  : 
       Fax                    : 
       E-mail                 : 
     Secondary Contact
       Contact Name           : 
       Telephone (primary)    : 
       Telephone (secondary)  : 
       Fax                    : 
       E-mail                 : 
     Additional Information   : (multiple lines)


13.  More Information

     Primary Data Center      : BEV
     Secondary Data Center    : BKG
     URL for More Information : http://www.gik.pw.edu.pl/
     Hardcopy on File
       Site Map               : X
       Site Diagram           : X
       Horizon Mask           : X
       Monument Description   : X
       Site Pictures          : X
     Additional Information   : (multiple lines)
     Antenna Graphics with Dimensions

TRM14532.00
4000ST L1/L2 Geodetic, Model 14532.00

                       ----+----                          <-- 0.0780 L1
                    /      +      \                       <-- 0.0680 L2
++----------------+-----------------+-----------------++  <-- 0.0630 TGP
++---------------+-------------------+----------------++  <-- 0.0600 BGP
                 |                   |
                  |                 |
                   |               |
                    +------x------+                       <-- 0.0 BPA=ARP

                    <--  0.140  -->                               BPA
                 <--     0.155     -->                            TPA
 <--                     0.467                      -->           NOTCHES
<--                      0.483                       -->          EDGE

ARP: Antenna Reference Point
L1 : L1 Phase Center                L2 : L2 Phase Center
TGP: Top of Ground Plane            BGP: Bottom of Ground Plane
BPA: Bottom of Preamplifier


Trimble: TRM14532.00

                       ----+----                          <-- 0.2710 L1
                    /      +      \                       <-- 0.2690 L2
++----------------+-----------------+-----------------++  <-- 0.2640 TGP
++---------------+-------------------+----------------++  <-- 0.2610 BGP
                 |                   |
                  |                 |
                   |               |
                    |             |
           +----------+---------+----------+     <--  0.1980 ARP=BPA
           |                               |
           |        Concrete Pillar        |--+  <--  0.0 <= Reference
Point
           |                               |  |
           |                               |--+


ARP: Antenna Reference Point
L1 : L1 Phase Center                   L2 : L2 Phase Center


SEPCHOKE_B3E6

                    ---------------                       <--  0.1550
                  /                 \
                 |                   |
+-----------------------------------------------------+   <--  0.1080  TCR
|                                                     |
|                                                     |
|                                                     |
|                                                     |
+-----------------+-----------------+-----------------+   <--  0.0480  BCR
                  |                 |
                  |                 |
                  |                 |
                  +--------x--------+                     <--  0.0000  BPA=ARP
                                                              (5/8" thread might
                                                               differ from BPA!)
                                                                       NOM=NRP
                  <--    0.1210   -->
<--                      0.3630                     -->