SNEC00CZE Site Information Form (site log v2.0)
International GNSS Service
See Instructions at:
https://files.igs.org/pub/station/general/sitelog_instr_v2.0.txt
0. Form
Prepared by (full name) : Vlamdimir Schenk
Date Prepared : 2010-07-01
Report Type : UPDATE
If Update:
Previous Site Log : snec00cze_20080630.log
Modified/Added Sections : 11, 13
1. Site Identification of the GNSS Monument
Site Name : Snezka
Nine Character ID : SNEC00CZE
Monument Inscription : CONCRETE PANEL
IERS DOMES Number : 11519M001
CDP Number : (A4)
Monument Description : PANEL ON BRICK CHIMNEY FILLED BY CONCRETE
Height of the Monument : 5.35 m
Monument Foundation : BEDROCK
Foundation Depth : 0.3 m
Marker Description : BRASS PLATE WITH SCREW
Date Installed : 2001-10-23T12:00Z
Geologic Characteristic : METAMORPHIC
Bedrock Type : (IGNEOUS/METAMORPHIC/SEDIMENTARY)
Bedrock Condition : FRESH
Fracture Spacing : over 200 cm
Fault zones nearby : NONE
Distance/activity : (multiple lines)
Additional Information : BUILDING FOUNDED JUST ON BEDROCK.
: The bedrock is MICA SCHIST / HORNFELS.
2. Site Location Information
City or Town : Pec (Pod Snezkou)
State or Province : Hradec Kralove District
Country or Region : CZE
Tectonic Plate : EURASIAN
Approximate Position (ITRF)
X coordinate (m) : 3894163.000
Y coordinate (m) : 1097514.900
Z coordinate (m) : 4916279.900
Latitude (N is +) : +504409.17
Longitude (E is +) : +0154423.07
Elevation (m,ellips.) : 1651.6
Additional Information : (multiple lines)
3. GNSS Receiver Information
3.1 Receiver Type : ASHTECH Z18
Satellite System : GPS+GLO
Serial Number : ZX420011205
Firmware Version : ZT16 0065
Elevation Cutoff Setting : 5 deg
Date Installed : 2001-10-23T12:00Z
Date Removed : 2006-03-07T14:00Z
Temperature Stabiliz. : (deg C) +/- (deg C)
Additional Information : NONE
3.2 Receiver Type : TPS GB-1000
Satellite System : GPS+GLO
Serial Number : 8QKMDE527LS
Firmware Version : 2.5 Jun,22,2005 p1
Elevation Cutoff Setting : 5 deg
Date Installed : 2006-03-07T14:00Z
Date Removed : 2009-06-10
Temperature Stabiliz. : (deg C) +/- (deg C)
Additional Information : NONE
3.x Receiver Type : (A20, from rcvr_ant.tab; see instructions)
Satellite System : (GPS+GLO+GAL+BDS+QZSS+IRNSS+SBAS)
Serial Number : (A20, but note the first A5 is used in SINEX)
Firmware Version : (A11)
Elevation Cutoff Setting : (deg)
Date Installed : (CCYY-MM-DDThh:mmZ)
Date Removed : (CCYY-MM-DDThh:mmZ)
Temperature Stabiliz. : (none or tolerance in degrees C)
Additional Information : (multiple lines)
4. GNSS Antenna Information
4.1 Antenna Type : ASH701946.2 SNOW
Serial Number : CR 320013201
Antenna Reference Point : BPA
Marker->ARP Up Ecc. (m) : 0.0000
Marker->ARP North Ecc(m) : 0.0000
Marker->ARP East Ecc(m) : 0.0000
Alignment from True N : 0 deg
Antenna Radome Type : SNOW
Radome Serial Number :
Antenna Cable Type : Orig. Ashtech suppl., BELDEN 8214 BRAID RG-8TYPE
Antenna Cable Length : 10 m
Date Installed : 2001-10-23T12:00Z
Date Removed : 2006-03-16T11:30Z
Additional Information : (multiple lines)
4.2 Antenna Type : TPSCR3_GGD CONE
Serial Number : 2170484
Antenna Reference Point : BPA
Marker->ARP Up Ecc. (m) : 0.1000
Marker->ARP North Ecc(m) : 0.0000
Marker->ARP East Ecc(m) : 0.0000
Alignment from True N : 0 deg
Antenna Radome Type : CONE
Radome Serial Number :
Antenna Cable Type : Orig. Ashtech suppl., BELDEN 8214 BRAID RG-8TYPE
Antenna Cable Length : 10 m
Date Installed : 2006-03-16T11:30Z
Date Removed : 2009-06-10
Additional Information : (multiple lines)
4.x Antenna Type : (A20, from rcvr_ant.tab; see instructions)
Serial Number : (A*, but note the first A5 is used in SINEX)
Antenna Reference Point : (BPA/BCR/XXX from "antenna.gra"; see instr.)
Marker->ARP Up Ecc. (m) : (F8.4)
Marker->ARP North Ecc(m) : (F8.4)
Marker->ARP East Ecc(m) : (F8.4)
Alignment from True N : (deg; + is clockwise/east)
Antenna Radome Type : (A4 from rcvr_ant.tab; see instructions)
Radome Serial Number :
Antenna Cable Type : (vendor & type number)
Antenna Cable Length : (m)
Date Installed : (CCYY-MM-DDThh:mmZ)
Date Removed : (CCYY-MM-DDThh:mmZ)
Additional Information : (multiple lines)
5. Surveyed Local Ties
5.x Tied Marker Name :
Tied Marker Usage : (SLR/VLBI/LOCAL CONTROL/FOOTPRINT/etc)
Tied Marker CDP Number : (A4)
Tied Marker DOMES Number : (A9)
Differential Components from GNSS Marker to the tied monument (ITRS)
dx (m) : (m)
dy (m) : (m)
dz (m) : (m)
Accuracy (mm) : (mm)
Survey method : (GPS CAMPAIGN/TRILATERATION/TRIANGULATION/etc)
Date Measured : (CCYY-MM-DDThh:mmZ)
Additional Information : (multiple lines)
6. Frequency Standard
6.1 Standard Type : INTERNAL
Input Frequency : (if external)
Effective Dates : 2001-10-23/CCYY-MM-DD
Notes : (multiple lines)
6.x Standard Type : (INTERNAL or EXTERNAL H-MASER/CESIUM/etc)
Input Frequency : (if external)
Effective Dates : (CCYY-MM-DD/CCYY-MM-DD)
Notes : (multiple lines)
7. Collocation Information
7.x Instrumentation Type : (GPS/GLONASS/DORIS/PRARE/SLR/VLBI/TIME/etc)
Status : (PERMANENT/MOBILE)
Effective Dates : (CCYY-MM-DD/CCYY-MM-DD)
Notes : (multiple lines)
8. Meteorological Instrumentation
8.1.1 Humidity Sensor Model : H982
Manufacturer : ANEMO
Serial Number : TH806662
Data Sampling Interval : 30 sec
Accuracy (% rel h) : 1 % rel h
Aspiration : NATURAL
Height Diff to Ant : 0 m
Calibration date : 2005-12-15
Effective Dates : 2006-03-16/CCYY-MM-DD
Notes : Integrated temp.& hum. module
: In surrounding located
: meteorological station SNIEZKA.
: See www.weatheronline.co.uk
: or www.wetteronline.de (Location: Sniezka)
8.1.x Humidity Sensor Model :
Manufacturer :
Serial Number :
Data Sampling Interval : (sec)
Accuracy (% rel h) : (% rel h)
Aspiration : (UNASPIRATED/NATURAL/FAN/etc)
Height Diff to Ant : (m)
Calibration date : (CCYY-MM-DD)
Effective Dates : (CCYY-MM-DD/CCYY-MM-DD)
Notes : (multiple lines)
8.2.1 Pressure Sensor Model : N
Manufacturer : ANEMO
Serial Number : 58/06
Data Sampling Interval : 30 sec
Accuracy : 2 hPa
Height Diff to Ant : -1 m
Calibration date : 2005-12-15
Effective Dates : 2006-03-16/CCYY-MM-DD
Notes : In surrounding located
: meteorological station SNIEZKA.
: See www.weatheronline.co.uk
: or www.wetteronline.de (Location: Sniezka)
8.2.x Pressure Sensor Model :
Manufacturer :
Serial Number :
Data Sampling Interval : (sec)
Accuracy : (hPa)
Height Diff to Ant : (m)
Calibration date : (CCYY-MM-DD)
Effective Dates : (CCYY-MM-DD/CCYY-MM-DD)
Notes : (multiple lines)
8.3.1 Temp. Sensor Model : T97
Manufacturer : ANEMO
Serial Number : TH806662
Data Sampling Interval : 30 sec
Accuracy : 0.2 deg C
Aspiration : NATURAL
Height Diff to Ant : 0 m
Calibration date : 2005-12-15
Effective Dates : 2006-03-16/CCYY-MM-DD
Notes : Integrated temp.& hum. module
: In surrounding located
: meteorological station SNIEZKA.
: See www.weatheronline.co.uk
: or www.wetteronline.de (Location: Sniezka)
8.3.x Temp. Sensor Model :
Manufacturer :
Serial Number :
Data Sampling Interval : (sec)
Accuracy : (deg C)
Aspiration : (UNASPIRATED/NATURAL/FAN/etc)
Height Diff to Ant : (m)
Calibration date : (CCYY-MM-DD)
Effective Dates : (CCYY-MM-DD/CCYY-MM-DD)
Notes : (multiple lines)
8.4.x Water Vapor Radiometer :
Manufacturer :
Serial Number :
Distance to Antenna : (m)
Height Diff to Ant : (m)
Calibration date : (CCYY-MM-DD)
Effective Dates : (CCYY-MM-DD/CCYY-MM-DD)
Notes : (multiple lines)
8.5.x Other Instrumentation : (multiple lines)
9. Local Ongoing Conditions Possibly Affecting Computed Position
9.1.x Radio Interferences : (TV/CELL PHONE ANTENNA/RADAR/etc)
Observed Degradations : (SN RATIO/DATA GAPS/etc)
Effective Dates : (CCYY-MM-DD/CCYY-MM-DD)
Additional Information : (multiple lines)
9.2.x Multipath Sources : (METAL ROOF/DOME/VLBI ANTENNA/etc)
Effective Dates : (CCYY-MM-DD/CCYY-MM-DD)
Additional Information : (multiple lines)
9.3.x Signal Obstructions : (TREES/BUILDINGS/etc)
Effective Dates : (CCYY-MM-DD/CCYY-MM-DD)
Additional Information : (multiple lines)
10. Local Episodic Effects Possibly Affecting Data Quality
10.x Date : (CCYY-MM-DD/CCYY-MM-DD)
Event : (TREE CLEARING/CONSTRUCTION/etc)
11. On-Site, Point of Contact Agency Information
Agency : Academy of Sciences of the Czech Republic
: Institute of Rock Structure and Mechanics
: Department of Engineering Geology
Preferred Abbreviation : IRSM CAS
Mailing Address : V Holesovickach 41
: CZ-182 09 Praha 8
: Czechia
Primary Contact
Contact Name :
Telephone (primary) :
Telephone (secondary) :
Fax :
E-mail :
Secondary Contact
Contact Name : Zdenek Fucik
Telephone (primary) : +420 266 009 362
Telephone (secondary) :
Fax : +420 284 680 105
E-mail : fucik@irsm.cas.cz
Additional Information : Third Contact
: RNDr. Zdenka Schenkova CSc.
: +420 266 009 337
: +420 266 009 338
: +420 284 680 105
: zdschenk@irsm.cas.cz
12. Responsible Agency (if different from 11.)
Agency : (multiple lines)
Preferred Abbreviation : (A10)
Mailing Address : (multiple lines)
Primary Contact
Contact Name :
Telephone (primary) :
Telephone (secondary) :
Fax :
E-mail :
Secondary Contact
Contact Name :
Telephone (primary) :
Telephone (secondary) :
Fax :
E-mail :
Additional Information : (multiple lines)
13. More Information
Primary Data Center : BKG
Secondary Data Center : BEV
URL for More Information : N/A
Hardcopy on File
Site Map : N/A
Site Diagram : N/A
Horizon Mask : N/A
Monument Description : N/A
Site Pictures : N/A
Additional Information : --- |
: --- |
: --- |
: --- |
: --- |
: --- |
: --- |
: --- |
: --- |
: --+
: :---
: --- |
: --- |
: --- |
: --- |
: --- |
: --- |
: --- |
: --- |
: --- |
: --+
: :---
Antenna Graphics with Dimensions
ASH701946.2
+---+ <-- 0.1400
/ \
/ + \ <-- 0.1284 L2
| + | <-- 0.1098 L1
+-------------------------------------------------+ <-- 0.1010 TCR
| |
| |
| |
| |
+-+-------------------------------------------------+-+ <-- 0.0380
+-------------------+-------------+-------------------+ <-- 0.0350 BCR
| |
| |
+------x------+ <-- 0.0 BPA=ARP
<-- 0.380 -->
Monument => +-----------------------------+
| |
Roof of the | Concrete Pillar |
building => -+ |
:--- |
: --- |
: --- |
: --- |
: --- |
: --- |
: --- |
: --- |
: --- |
: --+
: :---
ARP: Antenna Reference Point
L1 : L1 Phase Center L2 : L2 Phase Center
TCR: Top of Chokering BCR: Bottom of Chokering
TGP: Top of Ground Plane BGP: Bottom of Ground Plane
BPA: Bottom of Preamplifier
TPSCR3_GGD CONE
+---+
/ \
/ + \ <-- 0.1027 L2
| + | <-- 0.0803 L1
+-------------------------------------------------+ <-- TCR
| |
| |
| |
| |
+-+-------------------------------------------------+-+
+-------------------+-------------+-------------------+ <-- 0.0030 BCR
| |
| |
+------x------+ <-- 0.0 BPA=ARP
<-- 0.326 -->
Monument => +-----------------------------+
| |
Roof of the | Concrete Pillar |
building => -+ |
:--- |
: --- |
: --- |
: --- |
: --- |
: --- |
: --- |
: --- |
: --- |
: --+
: :---
ARP: Antenna Reference Point
L1 : L1 Phase Center L2 : L2 Phase Center
TCR: Top of Chokering BCR: Bottom of Chokering