TUC200GRC Site Information Form (site log v2.0)
     International GNSS Service
     See Instructions at:
       https://files.igs.org/pub/station/general/sitelog_instr_v2.0.txt


0.   Form

     Prepared by (full name)  : Stelios P. Mertikas
     Date Prepared            : 2020-07-17
     Report Type              : UPDATE
     If Update:
      Previous Site Log       : tuc200grc_20190329.log
      Modified/Added Sections : 3.8, 3.9, 13


1.   Site Identification of the GNSS Monument

     Site Name                : Technical University of Crete
     Nine Character ID        : TUC200GRC
     Monument Inscription     : 
     IERS DOMES Number        : 12617M003
     CDP Number               : (A4)
     Monument Description     : PILLAR
       Height of the Monument : 1.20 m
       Monument Foundation    : CONCRETE BLOCK
       Foundation Depth       : 0.70 m
     Marker Description       : CENTER OF ANTENNA MOUNTING PLATE
     Date Installed           : 2004-06-16T00:00Z
     Geologic Characteristic  : BEDROCK
       Bedrock Type           : SEDIMENTARY
       Bedrock Condition      : FRESH
       Fracture Spacing       : 1-10 cm
       Fault zones nearby     : NO
         Distance/activity    : (multiple lines)
     Additional Information   : TUC2 site is installed and maintained by
                              : the Geodesy and Geomatics Engineering Lab
                              : of the Mineral Resources Engineering Dept
                              : of the Technical University of Crete,
                              : Chania, Greece.


2.   Site Location Information

     City or Town             : Chania
     State or Province        : Crete
     Country or Region        : GRC
     Tectonic Plate           : EURASIAN
     Approximate Position (ITRF)
       X coordinate (m)       : 4744543.851
       Y coordinate (m)       : 2119411.870
       Z coordinate (m)       : 3686258.942
       Latitude (N is +)      : +353159.49
       Longitude (E is +)     : +0240414.01
       Elevation (m,ellips.)  : 161.0
     Additional Information   : TUC2 site is located in the Technical
                              : University of Crete Campus, Chania, Greece.


3.   GNSS Receiver Information

3.1  Receiver Type            : LEICA RS500
     Satellite System         : GPS
     Serial Number            : 0080199
     Firmware Version         : 4.2
     Elevation Cutoff Setting : 0 deg
     Date Installed           : 2004-06-20T00:00Z
     Date Removed             : 2008-12-10T00:00Z
     Temperature Stabiliz.    : none
     Additional Information   : (multiple lines)

3.2  Receiver Type            : LEICA GRX1200GGPRO
     Satellite System         : GPS
     Serial Number            : 352838
     Firmware Version         : 5.62/3.014
     Elevation Cutoff Setting : 0 deg
     Date Installed           : 2008-12-10T00:00Z
     Date Removed             : 2010-06-14T06:00Z
     Temperature Stabiliz.    : none
     Additional Information   : GRX1200GGPRO Receiver is capable of recording
                              : Glonass data. However this is not done because
                              : the Glonass option is locked on the receiver.
                              : The local leica vendor was not providing the
                              : option free of charge and the given budget at
                              : the time was not enough to unlock this option.
                              : On 17 March 2010 (DOY 2010/076, 13:20 UTC) the
                              : 'Code smoothing' tracking parameter was changed
                              : from 'Smoothed' to 'Not smoothed'.

3.3  Receiver Type            : LEICA GRX1200GGPRO
     Satellite System         : GPS
     Serial Number            : 352838
     Firmware Version         : 8.00/3.019
     Elevation Cutoff Setting : 0 deg
     Date Installed           : 2010-06-14T07:00Z
     Date Removed             : 2010-07-15T06:30Z
     Temperature Stabiliz.    : none
     Additional Information   : GRX1200GGPRO Receiver is capable of recording
                              : Glonass data. However this is not done because
                              : the Glonass option is locked on the receiver.
                              : The local leica vendor was not providing the
                              : option free of charge and the given budget at
                              : the time was not enough to unlock this option.
                              : On 17 March 2010 (DOY 2010/076, 13:20 UTC) the
                              : 'Code smoothing' tracking parameter was changed
                              : from 'Smoothed' to 'Not smoothed'.

3.4  Receiver Type            : LEICA GRX1200+GNSS
     Satellite System         : GPS+GLO
     Serial Number            : 495906
     Firmware Version         : 8.00/4.004
     Elevation Cutoff Setting : 0 deg
     Date Installed           : 2010-07-15T09:10Z
     Date Removed             : 2011-03-11T11:00Z
     Temperature Stabiliz.    : none
     Additional Information   : (multiple lines)

3.5  Receiver Type            : LEICA GRX1200+GNSS
     Satellite System         : GPS+GLO
     Serial Number            : 495906
     Firmware Version         : 8.10/4.004
     Elevation Cutoff Setting : 0 deg
     Date Installed           : 2011-03-11T11:00Z
     Date Removed             : 2014-05-05T08:00Z
     Temperature Stabiliz.    : none
     Additional Information   : (multiple lines)

3.6  Receiver Type            : LEICA GRX1200+GNSS
     Satellite System         : GPS+GLO
     Serial Number            : 495906
     Firmware Version         : 8.71/6.112
     Elevation Cutoff Setting : 0 deg
     Date Installed           : 2014-05-05T08:00Z
     Date Removed             : 2015-01-21T08:00Z
     Temperature Stabiliz.    : none
     Additional Information   : (multiple lines)

3.7  Receiver Type            : LEICA GRX1200+GNSS
     Satellite System         : GPS+GLO
     Serial Number            : 495906
     Firmware Version         : 9.20/6.404
     Elevation Cutoff Setting : 0 deg
     Date Installed           : 2015-01-21T08:00Z
     Date Removed             : 2019-03-29T07:00Z
     Temperature Stabiliz.    : none
     Additional Information   : (multiple lines)

3.8  Receiver Type            : LEICA GRX1200+GNSS
     Satellite System         : GPS+GLO
     Serial Number            : 495906
     Firmware Version         : 9.20/6.405
     Elevation Cutoff Setting : 0 deg
     Date Installed           : 2019-03-29T07:00Z
     Date Removed             : 2020-07-11T23:59Z
     Temperature Stabiliz.    : (deg C) +/- (deg C)
     Additional Information   : (multiple lines)

3.9  Receiver Type            : LEICA GRX1200+GNSS
     Satellite System         : GPS+GLO+GAL+BDS
     Serial Number            : 495906
     Firmware Version         : 9.20/6.405
     Elevation Cutoff Setting : 0 deg
     Date Installed           : 2020-07-12T00:00Z
     Date Removed             : CCYY-MM-DDThh:mmZ
     Temperature Stabiliz.    : (deg C) +/- (deg C)
     Additional Information   : (multiple lines)

3.x  Receiver Type            : (A20, from rcvr_ant.tab; see instructions)
     Satellite System         : (GPS+GLO+GAL+BDS+QZSS+IRNSS+SBAS)
     Serial Number            : (A20, but note the first A5 is used in SINEX)
     Firmware Version         : (A11)
     Elevation Cutoff Setting : (deg)
     Date Installed           : (CCYY-MM-DDThh:mmZ)
     Date Removed             : (CCYY-MM-DDThh:mmZ)
     Temperature Stabiliz.    : (none or tolerance in degrees C)
     Additional Information   : (multiple lines)


4.   GNSS Antenna Information

4.1  Antenna Type             : LEIAT504        NONE
     Serial Number            : 212
     Antenna Reference Point  : BPA
     Marker->ARP Up Ecc. (m)  :   0.0337
     Marker->ARP North Ecc(m) :   0.0000
     Marker->ARP East Ecc(m)  :   0.0000
     Alignment from True N    : 0 deg
     Antenna Radome Type      : NONE
     Radome Serial Number     : 
     Antenna Cable Type       : Leica supplied
     Antenna Cable Length     : 30 m
     Date Installed           : 2004-06-20T00:00Z
     Date Removed             : 2004-10-14T10:00Z
     Additional Information   : Removed due to poor quality of data
                              : (Satellite visibility problems in North
                              : sector)

4.2  Antenna Type             : LEIAT504        NONE
     Serial Number            : 424
     Antenna Reference Point  : BPA
     Marker->ARP Up Ecc. (m)  :   0.0343
     Marker->ARP North Ecc(m) :   0.0000
     Marker->ARP East Ecc(m)  :   0.0000
     Alignment from True N    : 0 deg
     Antenna Radome Type      : NONE
     Radome Serial Number     : 
     Antenna Cable Type       : Leica supplied
     Antenna Cable Length     : 30 m
     Date Installed           : 2004-10-14T10:00Z
     Date Removed             : 2010-07-15T06:30Z
     Additional Information   : (multiple lines)

4.3  Antenna Type             : LEIAR25.R3      NONE
     Serial Number            : 10020008
     Antenna Reference Point  : BPA
     Marker->ARP Up Ecc. (m)  :   0.0393
     Marker->ARP North Ecc(m) :   0.0000
     Marker->ARP East Ecc(m)  :   0.0000
     Alignment from True N    : 0 deg
     Antenna Radome Type      : NONE
     Radome Serial Number     : 
     Antenna Cable Type       : Leica supplied
     Antenna Cable Length     : 30 m
     Date Installed           : 2010-07-15T09:10Z
     Date Removed             : CCYY-MM-DDThh:mmZ
     Additional Information   : (multiple lines)

4.x  Antenna Type             : (A20, from rcvr_ant.tab; see instructions)
     Serial Number            : (A*, but note the first A5 is used in SINEX)
     Antenna Reference Point  : (BPA/BCR/XXX from "antenna.gra"; see instr.)
     Marker->ARP Up Ecc. (m)  : (F8.4)
     Marker->ARP North Ecc(m) : (F8.4)
     Marker->ARP East Ecc(m)  : (F8.4)
     Alignment from True N    : (deg; + is clockwise/east)
     Antenna Radome Type      : (A4 from rcvr_ant.tab; see instructions)
     Radome Serial Number     : 
     Antenna Cable Type       : (vendor & type number)
     Antenna Cable Length     : (m)
     Date Installed           : (CCYY-MM-DDThh:mmZ)
     Date Removed             : (CCYY-MM-DDThh:mmZ)
     Additional Information   : (multiple lines)


5.   Surveyed Local Ties

5.1  Tied Marker Name         : R00
     Tied Marker Usage        : LOCAL CONTROL
     Tied Marker CDP Number   : (A4)
     Tied Marker DOMES Number : (A9)
     Differential Components from GNSS Marker to the tied monument (ITRS)
       dx (m)                 : -0.200 m
       dy (m)                 : 0.090 m
       dz (m)                 : -1.003 m
     Accuracy (mm)            : 0.5 mm
     Survey method            : TRILATERATION/TRIANGULATION/LEVELLING
     Date Measured            : 2004-06-18T00:00Z
     Additional Information   : (multiple lines)

5.2  Tied Marker Name         : R01
     Tied Marker Usage        : LOCAL CONTROL
     Tied Marker CDP Number   : (A4)
     Tied Marker DOMES Number : (A9)
     Differential Components from GNSS Marker to the tied monument (ITRS)
       dx (m)                 : -8.300 m
       dy (m)                 : 6.820 m
       dz (m)                 : -0.704 m
     Accuracy (mm)            : 0.5 mm
     Survey method            : TRILATERATION/TRIANGULATION/LEVELLING
     Date Measured            : 2004-06-18T00:00Z
     Additional Information   : (multiple lines)

5.3  Tied Marker Name         : R02
     Tied Marker Usage        : LOCAL CONTROL
     Tied Marker CDP Number   : (A4)
     Tied Marker DOMES Number : (A9)
     Differential Components from GNSS Marker to the tied monument (ITRS)
       dx (m)                 : -0.650 m
       dy (m)                 : 9.070 m
       dz (m)                 : -0.864 m
     Accuracy (mm)            : 0.5 mm
     Survey method            : TRILATERATION/TRIANGULATION/LEVELLING
     Date Measured            : 2004-06-18T00:00Z
     Additional Information   : (multiple lines)

5.4  Tied Marker Name         : R03
     Tied Marker Usage        : LOCAL CONTROL
     Tied Marker CDP Number   : (A4)
     Tied Marker DOMES Number : (A9)
     Differential Components from GNSS Marker to the tied monument (ITRS)
       dx (m)                 : 10.580 m
       dy (m)                 : -4.750 m
       dz (m)                 : -0.992 m
     Accuracy (mm)            : 0.5 mm
     Survey method            : TRILATERATION/TRIANGULATION/LEVELLING
     Date Measured            : 2004-06-18T00:00Z
     Additional Information   : (multiple lines)

5.5  Tied Marker Name         : R04
     Tied Marker Usage        : LOCAL CONTROL
     Tied Marker CDP Number   : (A4)
     Tied Marker DOMES Number : (A9)
     Differential Components from GNSS Marker to the tied monument (ITRS)
       dx (m)                 : 5.600 m
       dy (m)                 : -3.060 m
       dz (m)                 : -0.949 m
     Accuracy (mm)            : 0.5 mm
     Survey method            : TRILATERATION/TRIANGULATION/LEVELLING
     Date Measured            : 2004-06-18T00:00Z
     Additional Information   : (multiple lines)

5.6  Tied Marker Name         : R05
     Tied Marker Usage        : LOCAL CONTROL
     Tied Marker CDP Number   : (A4)
     Tied Marker DOMES Number : (A9)
     Differential Components from GNSS Marker to the tied monument (ITRS)
       dx (m)                 : -0.270 m
       dy (m)                 : -17.120 m
       dz (m)                 : -0.541 m
     Accuracy (mm)            : 0.5 mm
     Survey method            : TRILATERATION/TRIANGULATION/LEVELLING
     Date Measured            : 2004-06-18T00:00Z
     Additional Information   : (multiple lines)

5.7  Tied Marker Name         : SLR0
     Tied Marker Usage        : SLR, LOCAL CONTROL, GPS
     Tied Marker CDP Number   : (A4)
     Tied Marker DOMES Number : (A9)
     Differential Components from GNSS Marker to the tied monument (ITRS)
       dx (m)                 : -1.090 m
       dy (m)                 : -16.450 m
       dz (m)                 : -0.544 m
     Accuracy (mm)            : 0.5 mm
     Survey method            : GPS CAMPAIGN/TRIANGULATION/LEVELLING
     Date Measured            : 2004-06-18T00:00Z
     Additional Information   : (multiple lines)

5.x  Tied Marker Name         : 
     Tied Marker Usage        : (SLR/VLBI/LOCAL CONTROL/FOOTPRINT/etc)
     Tied Marker CDP Number   : (A4)
     Tied Marker DOMES Number : (A9)
     Differential Components from GNSS Marker to the tied monument (ITRS)
       dx (m)                 : (m)
       dy (m)                 : (m)
       dz (m)                 : (m)
     Accuracy (mm)            : (mm)
     Survey method            : (GPS CAMPAIGN/TRILATERATION/TRIANGULATION/etc)
     Date Measured            : (CCYY-MM-DDThh:mmZ)
     Additional Information   : (multiple lines)


6.   Frequency Standard

6.1  Standard Type            : INTERNAL
       Input Frequency        : (if external)
       Effective Dates        : 2004-06-16/CCYY-MM-DD
       Notes                  : (multiple lines)

6.x  Standard Type            : (INTERNAL or EXTERNAL H-MASER/CESIUM/etc)
       Input Frequency        : (if external)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Notes                  : (multiple lines)


7.   Collocation Information

7.x  Instrumentation Type     : (GPS/GLONASS/DORIS/PRARE/SLR/VLBI/TIME/etc)
       Status                 : (PERMANENT/MOBILE)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Notes                  : (multiple lines)


8.   Meteorological Instrumentation

8.1.1  Humidity Sensor Model  : HMP45A-P Humidity and Temperature probe
       Manufacturer           : Vaisala Oyj, Finland
       Serial Number          : X1540004
       Data Sampling Interval :   180 sec
       Accuracy (% rel h)     : 1 % rel h
       Aspiration             : NATURAL
       Height Diff to Ant     : 16 m
       Calibration date       : 2003-05-27
       Effective Dates        : 2003-09-01/2006-12-12
       Notes                  : (multiple lines)

8.1.2  Humidity Sensor Model  : PAROSCIENTIFIC MET3
       Manufacturer           : PAROSCIENTIFIC
       Serial Number          : X1550001
       Data Sampling Interval :    60 sec
       Accuracy (% rel h)     : 1 % rel h
       Aspiration             : NATURAL
       Height Diff to Ant     : 2 m
       Calibration date       : 2006-10-10
       Effective Dates        : 2006-12-12/CCYY-MM-DD
       Notes                  : (multiple lines)

8.1.x  Humidity Sensor Model  : 
       Manufacturer           : 
       Serial Number          : 
       Data Sampling Interval : (sec)
       Accuracy (% rel h)     : (% rel h)
       Aspiration             : (UNASPIRATED/NATURAL/FAN/etc)
       Height Diff to Ant     : (m)
       Calibration date       : (CCYY-MM-DD)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Notes                  : (multiple lines)

8.2.1  Pressure Sensor Model  : PTU200 Class A PTU transmitter
       Manufacturer           : Vaisala Oyj, Finland
       Serial Number          : X1540004
       Data Sampling Interval : 180 sec
       Accuracy               : 0.07 hPa
       Height Diff to Ant     : 13 m
       Calibration date       : 2002-04-11
       Effective Dates        : 2003-09-01/2006-12-12
       Notes                  : (multiple lines)

8.2.2  Pressure Sensor Model  : PAROSCIENTIFIC MET3
       Manufacturer           : PAROSCIENTIFIC
       Serial Number          : X1550001
       Data Sampling Interval :  60 sec
       Accuracy               : 0.07 hPa
       Height Diff to Ant     : 2 m
       Calibration date       : 2006-10-10
       Effective Dates        : 2006-12-12/CCYY-MM-DD
       Notes                  : (multiple lines)

8.2.x  Pressure Sensor Model  : 
       Manufacturer           : 
       Serial Number          : 
       Data Sampling Interval : (sec)
       Accuracy               : (hPa)
       Height Diff to Ant     : (m)
       Calibration date       : (CCYY-MM-DD)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Notes                  : (multiple lines)

8.3.1  Temp. Sensor Model     : HMP45A-P Humidity and Temperature probe
       Manufacturer           : Vaisala Oyj, Finland
       Serial Number          : X1540004
       Data Sampling Interval : 180 sec
       Accuracy               : 0.15 deg C
       Aspiration             : NATURAL
       Height Diff to Ant     : 16 m
       Calibration date       : 2003-05-27
       Effective Dates        : 2003-09-01/2006-12-12
       Notes                  : (multiple lines)

8.3.2  Temp. Sensor Model     : PAROSCIENTIFIC MET3
       Manufacturer           : PAROSCIENTIFIC
       Serial Number          : X1550001
       Data Sampling Interval : 60 sec
       Accuracy               : 0.15 deg C
       Aspiration             : NATURAL
       Height Diff to Ant     : 2 m
       Calibration date       : 2006-10-10
       Effective Dates        : 2006-12-12/CCYY-MM-DD
       Notes                  : (multiple lines)

8.3.x  Temp. Sensor Model     : 
       Manufacturer           : 
       Serial Number          : 
       Data Sampling Interval : (sec)
       Accuracy               : (deg C)
       Aspiration             : (UNASPIRATED/NATURAL/FAN/etc)
       Height Diff to Ant     : (m)
       Calibration date       : (CCYY-MM-DD)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Notes                  : (multiple lines)

8.4.x  Water Vapor Radiometer : 
       Manufacturer           : 
       Serial Number          : 
       Distance to Antenna    : (m)
       Height Diff to Ant     : (m)
       Calibration date       : (CCYY-MM-DD)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Notes                  : (multiple lines)

8.5.x  Other Instrumentation  : (multiple lines)


9.   Local Ongoing Conditions Possibly Affecting Computed Position

9.1.x  Radio Interferences    : (TV/CELL PHONE ANTENNA/RADAR/etc)
       Observed Degradations  : (SN RATIO/DATA GAPS/etc)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Additional Information : (multiple lines)

9.2.x  Multipath Sources      : (METAL ROOF/DOME/VLBI ANTENNA/etc)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Additional Information : (multiple lines)

9.3.x  Signal Obstructions    : (TREES/BUILDINGS/etc)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Additional Information : (multiple lines)


10.  Local Episodic Effects Possibly Affecting Data Quality

10.x  Date                    : (CCYY-MM-DD/CCYY-MM-DD)
      Event                   : (TREE CLEARING/CONSTRUCTION/etc)


11.  On-Site, Point of Contact Agency Information

     Agency                   : Technical University of Crete
                              : Mineral Resources Engineering Department
                              : Geodesy and Geomatics Laboratory
     Preferred Abbreviation   : TUC
     Mailing Address          : University Campus
                              : 73100 Chania
                              : Greece
     Primary Contact
       Contact Name           : Stelios P. Mertikas
       Telephone (primary)    : +30 2821 037629
       Telephone (secondary)  : 
       Fax                    : +30 2821 037872
       E-mail                 : mertikas@mred.tuc.gr
     Secondary Contact
       Contact Name           : Xenophon A. Frantzis
       Telephone (primary)    : +30 2821 037687
       Telephone (secondary)  : 
       Fax                    : +30 2821 037872
       E-mail                 : xfratzis@mred.tuc.gr
     Additional Information   : (multiple lines)




12.  Responsible Agency (if different from 11.)

     Agency                   : (multiple lines)
     Preferred Abbreviation   : (A10)
     Mailing Address          : (multiple lines)
     Primary Contact
       Contact Name           : 
       Telephone (primary)    : 
       Telephone (secondary)  : 
       Fax                    : 
       E-mail                 : 
     Secondary Contact
       Contact Name           : 
       Telephone (primary)    : 
       Telephone (secondary)  : 
       Fax                    : 
       E-mail                 : 
     Additional Information   : (multiple lines)


13.  More Information

     Primary Data Center      : BEV
     Secondary Data Center    : BKG
     URL for More Information : http://www.geomatlab.tuc.gr
     Hardcopy on File
       Site Map               : Y
       Site Diagram           : Y
       Horizon Mask           : Y
       Monument Description   : Y
       Site Pictures          : Y
     Additional Information   : (multiple lines)
     Antenna Graphics with Dimensions

LEIAR25

                       +-------+                          <--  0.1995
                      /         \
                    +-           -+
                |---+-------------+---|                   <--  0.1456  TCR
             |---------------------------|
          |---------------------------------|
       |---------------------------------------|
    +---------------------------------------------+
    |                                             |
    |                                             |
  +-+---------------------------------------------+-+
  +-----------------+-------------+-----------------+     <--  0.0320  BCR
                    |             |
                    |             |
                    +------x------+                       <--  0.0000  BPA=ARP