VLFR00ITA Site Information Form (site log v2.0)
International GNSS Service
See Instructions at:
https://files.igs.org/pub/station/general/sitelog_instr_v2.0.txt
0. Form
Prepared by (full name) : Matera GNSS Team (gnss_op@est.asi.it)
Date Prepared : 2024-07-18
Report Type : UPDATE
If Update:
Previous Site Log : vlfr00ita_20240412.log
Modified/Added Sections : 11, 12
1. Site Identification of the GNSS Monument
Site Name : Villafranca di Verona, Verona
Nine Character ID : VLFR00ITA
Monument Inscription :
IERS DOMES Number : 14610M001
CDP Number : (A4)
Monument Description : STEEL
Height of the Monument : 1.5 m
Monument Foundation : STEEL RODS
Foundation Depth : 0.2 m
Marker Description : (CHISELLED CROSS/DIVOT/BRASS NAIL/etc)
Date Installed : 2019-09-16
Geologic Characteristic : BEDROCK
Bedrock Type : (IGNEOUS/METAMORPHIC/SEDIMENTARY)
Bedrock Condition : (FRESH/JOINTED/WEATHERED)
Fracture Spacing : (0 cm/1-10 cm/11-50 cm/51-200 cm/over 200 cm)
Fault zones nearby : (YES/NO/Name of the zone)
Distance/activity : (multiple lines)
Additional Information : (multiple lines)
2. Site Location Information
City or Town : Villafranca di Verona
State or Province : Verona
Country or Region : ITA
Tectonic Plate : EURASIAN
Approximate Position (ITRF)
X coordinate (m) : 4406451.442
Y coordinate (m) : 845931.423
Z coordinate (m) : 4518002.817
Latitude (N is +) : +452324.74
Longitude (E is +) : +0105201.85
Elevation (m,ellips.) : 133.1
Additional Information : (multiple lines)
3. GNSS Receiver Information
3.1 Receiver Type : LEICA GR30
Satellite System : GPS+GLO+GAL+BDS+QZSS+SBAS
Serial Number : 1705352
Firmware Version : 4.20/7.300
Elevation Cutoff Setting : 0 deg
Date Installed : 2019-09-16T09:00Z
Date Removed : 2023-11-17
Temperature Stabiliz. : none
Additional Information : (multiple lines)
3.2 Receiver Type : LEICA GR30
Satellite System : GPS+GLO+GAL+BDS+QZSS+SBAS
Serial Number : 1705352
Firmware Version : 4.70/7.813
Elevation Cutoff Setting : 0 deg
Date Installed : 2023-11-17
Date Removed : 2024-03-01
Temperature Stabiliz. : (deg C) +/- (deg C)
Additional Information : (multiple lines)
3.3 Receiver Type : LEICA GR30
Satellite System : GPS+GLO+GAL+BDS+QZSS+SBAS
Serial Number : 1705352
Firmware Version : 4.80/7.900
Elevation Cutoff Setting : 0 deg
Date Installed : 2024-03-01
Date Removed : CCYY-MM-DDThh:mmZ
Temperature Stabiliz. : (deg C) +/- (deg C)
Additional Information : (multiple lines)
3.x Receiver Type : (A20, from rcvr_ant.tab; see instructions)
Satellite System : (GPS+GLO+GAL+BDS+QZSS+IRNSS+SBAS)
Serial Number : (A20, but note the first A5 is used in SINEX)
Firmware Version : (A11)
Elevation Cutoff Setting : (deg)
Date Installed : (CCYY-MM-DDThh:mmZ)
Date Removed : (CCYY-MM-DDThh:mmZ)
Temperature Stabiliz. : (none or tolerance in degrees C)
Additional Information : (multiple lines)
4. GNSS Antenna Information
4.1 Antenna Type : LEIAR20 NONE
Serial Number : 19311015
Antenna Reference Point : BAM
Marker->ARP Up Ecc. (m) : 0.0000
Marker->ARP North Ecc(m) : 0.0000
Marker->ARP East Ecc(m) : 0.0000
Alignment from True N : 0 deg
Antenna Radome Type : NONE
Radome Serial Number :
Antenna Cable Type : Huber+Suhner GX 03272
Antenna Cable Length : 4.5 m
Date Installed : 2019-09-16T09:00Z
Date Removed : 2024-04-12
Additional Information : (multiple lines)
4.2 Antenna Type : LEIAR20 LEIM
Serial Number : 19311015
Antenna Reference Point : BAM
Marker->ARP Up Ecc. (m) : 0.0000
Marker->ARP North Ecc(m) : 0.0000
Marker->ARP East Ecc(m) : 0.0000
Alignment from True N : 0 deg
Antenna Radome Type : LEIM
Radome Serial Number :
Antenna Cable Type : Huber+Suhner GX 03272
Antenna Cable Length : 4.5 m
Date Installed : 2024-04-12
Date Removed : CCYY-MM-DDThh:mmZ
Additional Information : Cleaned antenna and installed Dome
4.x Antenna Type : (A20, from rcvr_ant.tab; see instructions)
Serial Number : (A*, but note the first A5 is used in SINEX)
Antenna Reference Point : (BPA/BCR/XXX from "antenna.gra"; see instr.)
Marker->ARP Up Ecc. (m) : (F8.4)
Marker->ARP North Ecc(m) : (F8.4)
Marker->ARP East Ecc(m) : (F8.4)
Alignment from True N : (deg; + is clockwise/east)
Antenna Radome Type : (A4 from rcvr_ant.tab; see instructions)
Radome Serial Number :
Antenna Cable Type : (vendor & type number)
Antenna Cable Length : (m)
Date Installed : (CCYY-MM-DDThh:mmZ)
Date Removed : (CCYY-MM-DDThh:mmZ)
Additional Information : (multiple lines)
5. Surveyed Local Ties
5.x Tied Marker Name :
Tied Marker Usage : (SLR/VLBI/LOCAL CONTROL/FOOTPRINT/etc)
Tied Marker CDP Number : (A4)
Tied Marker DOMES Number : (A9)
Differential Components from GNSS Marker to the tied monument (ITRS)
dx (m) : (m)
dy (m) : (m)
dz (m) : (m)
Accuracy (mm) : (mm)
Survey method : (GPS CAMPAIGN/TRILATERATION/TRIANGULATION/etc)
Date Measured : (CCYY-MM-DDThh:mmZ)
Additional Information : (multiple lines)
6. Frequency Standard
6.1 Standard Type : INTERNAL
Input Frequency : (if external)
Effective Dates : 2019-07-26/CCYY-MM-DD
Notes : (multiple lines)
6.x Standard Type : (INTERNAL or EXTERNAL H-MASER/CESIUM/etc)
Input Frequency : (if external)
Effective Dates : (CCYY-MM-DD/CCYY-MM-DD)
Notes : (multiple lines)
7. Collocation Information
7.x Instrumentation Type : (GPS/GLONASS/DORIS/PRARE/SLR/VLBI/TIME/etc)
Status : (PERMANENT/MOBILE)
Effective Dates : (CCYY-MM-DD/CCYY-MM-DD)
Notes : (multiple lines)
8. Meteorological Instrumentation
8.1.1 Humidity Sensor Model : PTU300
Manufacturer : Vaisala
Serial Number : V0720848
Data Sampling Interval : 30 sec
Accuracy (% rel h) : 1 % rel h
Aspiration : (UNASPIRATED/NATURAL/FAN/etc)
Height Diff to Ant : -0.2 m
Calibration date : 2019-04-01
Effective Dates : 2024-04-12/CCYY-MM-DD
Notes : (multiple lines)
8.1.x Humidity Sensor Model :
Manufacturer :
Serial Number :
Data Sampling Interval : (sec)
Accuracy (% rel h) : (% rel h)
Aspiration : (UNASPIRATED/NATURAL/FAN/etc)
Height Diff to Ant : (m)
Calibration date : (CCYY-MM-DD)
Effective Dates : (CCYY-MM-DD/CCYY-MM-DD)
Notes : (multiple lines)
8.2.1 Pressure Sensor Model : PTU300
Manufacturer : Vaisala
Serial Number : V0720848
Data Sampling Interval : 30 sec
Accuracy : 0.3 hPa
Height Diff to Ant : -0.2 m
Calibration date : 2019-04-01
Effective Dates : 2024-04-12/CCYY-MM-DD
Notes : (multiple lines)
8.2.x Pressure Sensor Model :
Manufacturer :
Serial Number :
Data Sampling Interval : (sec)
Accuracy : (hPa)
Height Diff to Ant : (m)
Calibration date : (CCYY-MM-DD)
Effective Dates : (CCYY-MM-DD/CCYY-MM-DD)
Notes : (multiple lines)
8.3.1 Temp. Sensor Model : PTU300
Manufacturer : Vaisala
Serial Number : V0720848
Data Sampling Interval : 30 sec
Accuracy : 0.2 deg C
Aspiration : (UNASPIRATED/NATURAL/FAN/etc)
Height Diff to Ant : -0.2 m
Calibration date : 2019-04-01
Effective Dates : 2024-04-12/CCYY-MM-DD
Notes : (multiple lines)
8.3.x Temp. Sensor Model :
Manufacturer :
Serial Number :
Data Sampling Interval : (sec)
Accuracy : (deg C)
Aspiration : (UNASPIRATED/NATURAL/FAN/etc)
Height Diff to Ant : (m)
Calibration date : (CCYY-MM-DD)
Effective Dates : (CCYY-MM-DD/CCYY-MM-DD)
Notes : (multiple lines)
8.4.x Water Vapor Radiometer :
Manufacturer :
Serial Number :
Distance to Antenna : (m)
Height Diff to Ant : (m)
Calibration date : (CCYY-MM-DD)
Effective Dates : (CCYY-MM-DD/CCYY-MM-DD)
Notes : (multiple lines)
8.5.x Other Instrumentation : (multiple lines)
9. Local Ongoing Conditions Possibly Affecting Computed Position
9.1.x Radio Interferences : (TV/CELL PHONE ANTENNA/RADAR/etc)
Observed Degradations : (SN RATIO/DATA GAPS/etc)
Effective Dates : (CCYY-MM-DD/CCYY-MM-DD)
Additional Information : (multiple lines)
9.2.x Multipath Sources : (METAL ROOF/DOME/VLBI ANTENNA/etc)
Effective Dates : (CCYY-MM-DD/CCYY-MM-DD)
Additional Information : (multiple lines)
9.3.x Signal Obstructions : (TREES/BUILDINGS/etc)
Effective Dates : (CCYY-MM-DD/CCYY-MM-DD)
Additional Information : (multiple lines)
10. Local Episodic Effects Possibly Affecting Data Quality
10.x Date : (CCYY-MM-DD/CCYY-MM-DD)
Event : (TREE CLEARING/CONSTRUCTION/etc)
11. On-Site, Point of Contact Agency Information
Agency : Agenzia Spaziale Italiana
: Centro di Geodesia Spaziale
Preferred Abbreviation : ASI
Mailing Address : Contrada Terlecchia
: 75100 Matera
: Italy
Primary Contact
Contact Name : Matera GNSS Team
Telephone (primary) :
Telephone (secondary) :
Fax :
E-mail : gnss_op@est.asi.it
Secondary Contact
Contact Name : Giuseppe Colucci
Telephone (primary) : +39 0835 377574
Telephone (secondary) :
Fax : +39 06 4099 9941
E-mail : giuseppe.colucci@e-geos.it
Additional Information : (multiple lines)
12. Responsible Agency (if different from 11.)
Agency : (multiple lines)
Preferred Abbreviation : (A10)
Mailing Address : (multiple lines)
Primary Contact
Contact Name :
Telephone (primary) :
Telephone (secondary) :
Fax :
E-mail :
Secondary Contact
Contact Name :
Telephone (primary) :
Telephone (secondary) :
Fax :
E-mail :
Additional Information : (multiple lines)
13. More Information
Primary Data Center : ASI
Secondary Data Center : BKG
URL for More Information :
Hardcopy on File
Site Map : (Y or URL)
Site Diagram : (Y or URL)
Horizon Mask : (Y or URL)
Monument Description : (Y or URL)
Site Pictures : (Y or URL)
Additional Information : (multiple lines)
Antenna Graphics with Dimensions
LEIAR20
+-----+ <-- 0.1613
/ \
| |
+----------------+-----------+----------------+ <-- 0.1113 TCR
| |
| |
| |
| |
+-+---------------------------------------------+-+
+------------------+-----------+------------------+ <-- 0.0323 BCR
| |
| |
+----+ +----+ <-- 0.0013 BPA
+x+ <-- 0.0000 BAM=ARP
NOM=NRP
<-- 0.3200 -->